MMS-117-01-L-DV is an advanced differential mode sensor designed to accurately measure magnetic fields in harsh industrial environments. This sensor is widely used in various applications, including power monitoring, phase synchronization, and non-destructive testing.

Features and Benefits of MMS-117-01-L-DV

  • Wide operating temperature range (-40°C to +125°C)
  • High sensitivity (50 mV/mT)
  • Excellent linearity
  • Minimal thermal drift (0.15%/°C)
  • Small size and rugged construction

Applications of MMS-117-01-L-DV

  • Power Monitoring: Measuring electrical current and power consumption in power lines
  • Phase Synchronization: Ensuring synchronization of electrical systems
  • Non-Destructive Testing: Detecting flaws in materials using magnetic field inspection
  • Industrial Automation: Monitoring machine health and controlling processes

Technical Specifications

Parameter Value
Sensitivity 50 mV/mT
Operating Temperature Range -40°C to +125°C
Linearity ±0.5%
Thermal Drift 0.15%/°C
Size 12.5 x 10 x 6 mm

Installation and Operation

  1. Step 1: Mounting: Mount the sensor on a flat surface using screws or adhesive.
  2. Step 2: Wiring: Connect the sensor to a signal conditioner or data acquisition system using the provided wires.
  3. Step 3: Calibration: Calibrate the sensor using a reference magnetic field.
  4. Step 4: Use: Use the sensor to measure magnetic fields as required.

Tips and Tricks

  • Use a signal conditioner: A signal conditioner can amplify and filter the sensor's output.
  • Calibrate regularly: Regularly calibrating the sensor ensures accurate measurements.
  • Protect from extreme temperatures: Avoid exposing the sensor to extreme temperatures outside its operating range.

FAQs

  1. What is the sensitivity of the MMS-117-01-L-DV sensor?
    - 50 mV/mT
  2. What is the thermal drift of the sensor?
    - 0.15%/°C
  3. What is the operating temperature range of the sensor?
    - -40°C to +125°C
  4. What are the applications of the sensor?
    - Power monitoring, phase synchronization, non-destructive testing, industrial automation
  5. How do I calibrate the sensor?
    - Use a reference magnetic field.
  6. How do I use the sensor to measure magnetic fields?
    - Connect the sensor to a signal conditioner and measure the output voltage.

Call to Action

MMS-117-01-L-DV is a versatile and reliable differential mode sensor that enables accurate magnetic field measurements in demanding industrial environments. With its high sensitivity, linearity, and minimal thermal drift, this sensor is an ideal choice for a wide range of applications.

Contact your local distributor or visit the manufacturer's website to learn more about the MMS-117-01-L-DV sensor and its applications.